The Index

Standards, test methods and accreditations, grouped by the Center of Excellence that runs them.

E3 & Environmental  Fullerton, CA

Visit location →
Standards
Standard
MIL-STD-461
Electromagnetic interference control for subsystems and equipment
Learn more →
Standard
MIL-STD-464
Electromagnetic environmental effects (E3) requirements at the platform or system level
Standard
MIL-STD-704
Specifies the characteristics and quality of electrical power supplied to airborne equipment
Standard
MIL-STD-1275
28 VDC power characteristics and transient requirements for electrical equipment used in military vehicles
Standard
MIL-STD-1399 Section 300
Shipboard AC power interface requirements for equipment connected to naval vessel power systems
Standard
RTCA/DO-160 Section 21
Emission of radio frequency energy from airborne equipment
Standard
MIL-STD-202
Evaluates reliability and durability of electronic and electrical components.
Standard
MIL-STD-1344
Evaluates performance of electrical connectors
Standard
EIA-364
Test procedures for electrical connectors and sockets. Fullerton is DLA-approved for this specification.
Test Methods
Test method
Radiated susceptibility
Immunity to radiated fields, up to 200 V/m from 10 kHz to 40 GHz
Test method
Radiated emissions
Measures radiated energy from equipment, 30 Hz to 40 GHz
Test method
HIRF testing
High-intensity radiated fields, 100 MHz to 18 GHz, up to 7200 V/m peak
Test method
Indirect lightning
Single stroke, multiple stroke and multiple burst, to Level 5 of RTCA/DO-160
Test method
Electrostatic discharge
ESD immunity testing up to 30 kV
Test method
Electromagnetic pulse (EMP)
Pulsed field exposure to 50 kV/m
Test method
Vibration testing
Single and dual shaker systems, up to 70,000 lbs force on tandem shakers
Test method
Highly accelerated life testing (HALT)
Stress testing beyond specification limits to reveal design margins
Test method
Hydraulic and pneumatic testing
Pressure impulse, flow, proof and burst testing

Space & Environmental Simulation  Santa Clarita, CA

Visit location →
Standards
Standard
SAE ARP 1401
Water-in-fuel fuel icing testing on aerospace fuel system components
Standard
MIL-F-8615
Fuel icing and contaminated fuel testing
Standard
RTCA/DO-160
Qualification requirement for fuel line parts and subsystems
Standard
MIL-STD-810
Qualification requirement for fuel line parts and subsystems
Test Methods
Test method
Thermal vacuum (TVAC)
Thermal cycling under vacuum to simulate space
Learn more →
Test method
Space simulation
Launch and on-orbit environment qualification
Test method
Shock and vibration testing
Dynamics qualification on shakers and shock machines
Test method
Acceleration and centrifuge testing
Sustained g-loading of hardware on a centrifuge
Test method
Combined environments testing
Simultaneous thermal, vibration and altitude exposure
Test method
Acoustic testing
Reverberation chambers to 167 dB and progressive wave tubes to 174+ dB
Test method
Pyroshock simulation
Shaker simulated, metal to metal impact and true ordnance
Test method
Hypersonic simulation
Material coupon and full-scale testing, with thermal exposure up to 4,000°F
Test method
Fuel icing and contamination
Water-in-fuel and contaminated fuel testing on fuel system components

Naval Systems & Heavyweight Shock  Rustburg, VA

Visit location →
Standards
Standard
MIL-DTL-901
High-impact shock tests for shipboard machinery, equipment and systems
Learn more →
Standard
MIL-STD-167
Mechanical vibration of shipboard equipment
Learn more →
Test Methods
Test method
Barge testing
Floating shock platform tests for heavyweight shipboard equipment
Test method
Deck Simulating Shock Machine (DSSM)
Land-based alternative for heavyweight testing of Class II shock-isolated equipment
Test method
Temperature and humidity testing
Environmental simulation for naval, avionics and other rugged equipment

Aerospace Environmental Simulation  Orlando, FL

Visit location →
Standards
Standard
MIL-STD-810
Environmental engineering considerations and laboratory tests
Learn more →
Standard
RTCA/DO-160
Environmental conditions and test procedures for airborne equipment
Learn more →
Standard
ISTA 1A–1D, 2A, 2B
Packaged-product transit testing. Orlando is ISTA-certified for these procedures.
Standard
SAE ARP4378, ARP4946, ARP1383
Common test specifications for hydraulics testing
Test Methods
Test method
MIL-STD-810 Method 510
Evaluates product’s ability to resist the effects of blowing sand and dust while maintaining required performance
Test method
Environmental stress screening (ESS)
Applied stress screening to catch latent defects before delivery
Test method
Explosive atmosphere
Chamber testing to 71°C and 50,000 ft altitude
Test method
Waterproofness testing
IPX3 through IPX7, including spray, rain and immersion
Test method
Mechanical shock
Free-fall and shaker shock, classical and SRS
Test method
Hydraulics testing
Endurance, impulse, burst and proof pressure, leakage and cold start

Ballistics & Sports Equipment  Belcamp, MD

Visit location →
Standards
Standard
NIJ 0101.07
Ballistic resistance of body armor. Belcamp is approved under the NIJ Compliance Testing Program for 0101.06 and 0101.07.
Standard
MIL-STD-662
V50 ballistic limit test for armor
Standard
NIJ 0115.00
Stab resistance of personal body armor
Standard
NOCSAE
Testing of personal safety equipment for contact sport athletes
Standard
SAAMI
Ammunition testing protocols, alongside FBI and customized test plans
Accreditation
NVLAP
NIST National Voluntary Laboratory Accreditation Program. Belcamp, MD is NVLAP accredited.
Test Methods
Test method
Blast testing
Structural and glazing response to blast loading
Test method
CT Scanning
Inspection that evaluates hardware without damaging it
Test method
Ballistic resistance testing
Material impact testing on climate-controlled indoor ranges
Test method
Ammunition testing
Pressure and velocity measurement, proof, cook-off and primer sensitivity
Test method
Firearms testing
Accuracy and dispersion, rate of fire, barrel life, endurance and recoil
Test method
Helmet impact testing
Sport and military helmets, to standards from NCAA and ASTM to DOT and MIL-STD

Energetics & Munitions  Camden, AR

Visit location →
Standards
Standard
MIL-STD-2105
Hazard assessment tests for non-nuclear munitions
Standard
MIL-DTL-901
Lightweight shipboard shock
Standard
MIL-STD-810
Applicable defense standard for testing on the secure rocket range
Standard
49 CFR
Compliance for shipping hazardous materials
Test Methods
Test method
Arena testing (ITOP 4-2-813)
Warhead fragment characterization on an instrumented range
Test method
Lot acceptance testing
Sample testing that releases a production lot
Test method
Bullet impact testing
Small and medium caliber ammunition impacts
Test method
Fragment impact testing
Single fragment impact testing to MIL-STD-2105
Test method
External fire and cook-off
External fire, fast and slow cook-off testing
Test method
Ballistic limit (V50)
Ballistic limit of materials and projectiles

Independently Recognized & Verifiable

Certificates, scopes and verification links live on the Accreditations page.

View Accreditations
Company-wide
CMMC Level 2 Certified
The U.S. Department of Defense standard for protecting Controlled Unclassified Information.
View details →Read the press release →
Belcamp, Fullerton, Orlando, Santa Clarita
ISO/IEC 17025 (A2LA)
Laboratory competence for the tests on each site’s scope of accreditation.
View details →
Belcamp, MD
NVLAP
Accreditation under the NIST National Voluntary Laboratory Accreditation Program.
View details →
Belcamp, MD
NIJ Compliance Testing Program
Approved to conduct body armor compliance testing to NIJ standards, including 0101.06 and 0101.07.
View details →
Fullerton, CA
Defense Logistics Agency
Approved for testing to EIA-364, MIL-STD-202 and MIL-STD-1344.
View details →
Orlando, FL
ISTA Certified
Certified for ISTA transit test procedures 1A, 1B, 1C, 1D, 2A and 2B.
View details →

From Spec to Schedule

Built by You. Tested by Us.

1
Share the standard
Designation, revision and the test levels in your procurement spec.
2
We review it
Our team reviews your spec and connects you with the right lab.
3
You get a quote
Scope, schedule and cost from the lab that will run the test.
Request a Quote